About ADR Security in Texas
ACR-2401
B11732

 

Life Safety

Trust ADR's local get-it-done experience deliver your life safety project on-time and on-budget. ADR performs NFPA and Texas State required tests and inspections to assure that your fire alarm system is performing to its optimal level. Call ADR now at (877) 481-6730 for fast and friendly service.

  • Fire alarms - individual components to fully integrated systems
  • Integrated burglar/life components & safety systems
  • NFPA & State of Texas tests & inspections
  • Maintenance Contracts
  • Fast track permit options
  • Local get-it-done experience
  • 24/7 Service
  • Bonded and insured
 
Call ADR now at (877) 481-6730 to discuss your Life Safety project. 
MRP-2001 Deluge/Preaction Control Panel - MRP-2002 Agent Release Control Panel

Suppression Control Panels

Fire-Lite’s new UL 864 Ninth Edition listed releasing panels are designed with the latest in microprocessor technology to meet the most demanding conventional releasing applications. With the flexibility and extra high reliability found typically only in advanced systems, he new Deluge/Preaction and Agent release models feature a host of new features, such as built-in easy-to-use programming templates.

 

MRP-2001 DELUGE/PREACTION CONTROL PANEL
• Six-zone Style B (Class B) or Six-zone Style D (Class A) with optional modules
• Four Programmable Output Circuits Style Y (Class B) or Four Programmable Output Circuits Style Z (Class A) with optional modules
• Outputs programmable for Releasing Solenoids
• Dual hazard operation
• Adjustable waterflow discharge timer and two soak timers
• Cross-zone capability
• Pre-programmed and custom application templates
• Built-in NAC synchronization for System Sensor, Wheelock, Gentex, Faraday and Amseco devices
• Built in programmer: Integral 80 character LCD display with backlighting and keypad
• Annunciator bus supports up to 8 devices, including new ANN-80 LCD Remote Annunciator, remote serial or parallel printer gateway, and LED graphic annunciator
• 7.0 amps total usable current


 

MRP-2002 AGENT RELEASE CONTROL PANEL
• Six-zone Style B (Class B) or Six-zone Style D (Class A) with optional modules
• Four Programmable Output Circuits Style Y (Class B) or Four Programmable Output Circuits Style Z (Class A) with optional modules
• Outputs programmable for Releasing Solenoids
• Dual hazard operation
• Adjustable pre-discharge, discharge and waterflow delay timers
• Programmable Abort operation
• Cross-zone capability
• Pre-programmed and custom application templates
• Built-in NAC synchronization for System Sensor, Wheelock, Gentex, Faraday and Amseco devices
• Built in programmer: Integral 80 character LCD display with backlighting and keypad
• Annunciator bus supports up to 8 devices, including new ANN-80 CD Remote Annunciator, remote serial or parallel printer gateway, and LED graphic annunciator
• 7.0 amps total usable current

 


Pull Stations

BG-8

The BG-8, conventional, single action metal fire alarm pull station for those jurisdictions where metal pull stations are still required.

 

 




BG-12 Series
The BG-12 Series is a cost-effective, non-coded series of fire alarm pull stations. Available in both conventional and addressable versions, including single and dual actions, with either key lock or hex key, these Lexan® pull stations are typically specified and desired by most architects and engineers.

 

Call ADR now at (877) 481-6730 to discuss your Life Safety project. 

Conventional Fire Control Panels

Fire-Lite's UL 9th Edition listed 24 Volt conventional fire alarm control panels bring the latest in microprocessor technology to conventional fire controls and are easy-to-install, program and operate. With two-zone, four-zone, five-zone and ten-zone configurations, these units offer a variety of options to meet most local, state and national requirements.

 

MS-5UD
UPLOAD/DOWNLOAD

• Five-zone Style B (Class B) or Five-zone Style D (Class A) with optional module
• Four NAC Circuits Style Y (Class B) or Four NAC Circuits Style Z (Class A) with optional modules
• Built-in NAC synchronization for System Sensor, Wheelock, Gentex, Faraday and Amseco devices
• Integral 80 character LCD display with backlighting and keypad
• Annunciator bus supports up to 8 devices, including new ANN-80 LCD Remote Annunciator, ANN-S/PG remote serial or parallel printer gateway, ANN-RLY, 10 form C relay board, ANN-LED Zone annunciator and ANN-I/O LED driver board for graphic annunciators.
• Built-in two-line digital communicator for off premises monitoring
• Three Form-C programmable relays
• 3.0 amps total usable current
 
 
 
MS-10UD
UPLOAD/DOWNLOAD

• Ten-zone Style B (Class B) or Ten-zone Style D (Class A) with optional module
• Four NAC Circuits Style Y (Class B) or Four NAC Circuits Style Z (Class A) with optional modules
• Built-in NAC synchronization for System Sensor, Wheelock, Gentex, Faraday and Amseco devices
• Built in programmer: Integral 80 character LCD display with backlighting and keypad
• Annunciator bus supports up to 8 devices, including new ANN-80 LCD Remote Annunciator, ANN-S/PG remote serial or parallel printer gateway, ANN-RLY, 10 form C relay board, ANN-LED Zone annunciator and ANN-I/O LED driver board for graphic annunciators.
• Built-in two-line digital communicator for off premises monitoring
• Three Form-C programmable relays
• 7.0 amps total shared power 

 MS-2

• Two initiating zones compatible with 2- and 4-wire smoke detectors, one zone programmable for combo, supervisory and waterflow
• One Notification Appliance Circuit (NAC) with built-in horn/strobe synchronization for System Sensor®, Wheelock® or Gentex® with selectable silence.
• Also compatible with conventional input devices such as twoand four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices.
• 3.0 amps total usable current


 

MS-4

• Four initiating zones compatible with 2- and 4-wire smoke detectors, one zone programmable for combo, supervisory and waterflow
• Two NACs with built-in horn/strobe synchronization for System Sensor®, Wheelock® or Gentex® with selectable silence
• Optional module to convert all four initiating zones and two NACs to Class A
• Also compatible with conventional input devices such as twoand four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices.
• Compatible with System Sensor's smoke detectors, providing "EZ Walk Test" and a Remote Maintenance Signal (panel is offered as i3 Ready, no additional modules needed)
• 3.0 amps total usable current and expandable to 6.0 amps total with optional second transformer
• Options include a plug-in 4XTMF transmitter module, a 4XLMF module to support LED annunciators, and a plug-in 4XZMF zone relay module 

 

Click here to read more



 

Call ADR now at (877) 481-6730 to discuss your Life Safety project.